Parameter:
|
735
|
730
|
720
|
710
|
700
|
Units
|
Comments
|
PRESSURE RANGES: |
Pressure Range (1):
|
0 - 2 through 0 - 300
|
psig
|
intermediate ranges available |
a |
0 - 15
through
0 - 300
|
0-5
through
0-300
|
psig
|
735 only available in psig |
Proof Pressure:
|
1.5
|
x FS
|
a |
Burst Pressure:
|
2.0
|
x FS
|
a |
STATIC PERFORMANCE: |
Static Accuracy (2):
|
±0.05
|
±0.10
|
±0.25
|
±0.50
|
±1.00
|
% FSO
BFSL
|
a |
Thermal Error (3):
|
±0.05
|
±0.10
|
%FSO/șC
|
worst case |
Resolution:
|
Infinitesimal
|
a |
a |
ENVIRONMENTAL: |
Wetted Materials (1):
|
316 SS or Titanium, Fluorocarbon
|
a |
a |
Compensated Temp Range (1):
|
0 to 50
|
șC
|
options available |
Operating Temp Range:
|
-20 to 60
|
șC
|
options available |
ELECTRICAL: |
Excitation:
|
2.5 - 10
5
9 - 30
|
VDC |
mV output (ratiometric)
mV output (non-ratiometric)
mA, VDC output |
Input Current:
|
3.5
20
|
mA max |
mV, VDC output
mA output |
Output:
|
2.5 - 10
0 - 100 (4)
0 - 5
4 - 20
|
mV/V
mV
VDC
mA
|
ratiometric, depending on range
non-ratiometric
3 wire
2 wire |
Zero Offset:
|
±5
±60
±0.12
|
mV
mV
mA
|
mV output
VDC output
mA output |
Insulation Resistance:
|
100
|
megaohms |
at 50 VDC |
Circuit Protection:
|
Polarity, surge/shorted output
|
a |
a |
PHYSICAL: |
Weight:
|
198
|
grams
|
excluding cable |
Cable:
|
Self-sealing polyurethane jacketed shielded cable with polyethylene
vent tube. 90 kilograms pull strength. Conductors are 22 AWG.
Tefzel jacket optional.
|
70 g/m
|
Specify cable length as separate line item. |
Mounting Provisions:
|
Suspended by cable. For turbulent conditions, specify optional
mount bracket or conduit fitting.
|
a |
a |