|  | PH 
          Meters
 Hanna 
          HI 991001/2 Waterproof pH & Temperature Meter
 HI 991001 Probe 
          Specifications
           
            | Range | pH | -2.00 
                to 16.00 pH |   
            | Range | Temperature | -5.0 
                to 105.0°C / 23.0 to 221.0°F |   
            | Resolution | pH | 0.01 
                pH |   
            | Resolution | Temperature | 0.1°C 
                / 0.1°F |   
            | Accuracy | pH | ±0.02 
                pH |   
            | Accuracy | Temperature | ±0.5°C 
                (up to 60°C), ±1°C (outside);±1.0°F (up to 140°F), ±2°F (outside)
 |   
            | pH Calibration |   | automatic, 
                1 or 2 point with 2 sets of memorized buffer values(pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
 |   
            | Temperature Compensation |   | automatic, 
                -5 to 105°C (23 to 221°F) for pH readings |   
            | Electrode |   | HI 
                1296D amplified pH electrode withinternal temperature sensor, DIN connector and 1 m (3.3') cable 
                (included)
 |    HI 991002 Probe 
          Specifications
           
            | Range | pH | -2.00 
                to 16.00 pH |   
            | Range | mV | ±1999 
                mV |   
            | Range | Temperature | -5.0 
                to 105.0°C / 23.0 to 221.0°F |   
            | Resolution | pH | 0.01 
                pH |   
            | Resolution | mV | 1 
                mV |   
            | Resolution | Temperature | 0.1°C 
                / 0.1°F |   
            | Accuracy | pH | ±0.02 
                pH |   
            | Accuracy | mV | ±2 
                mV |   
            | Accuracy | Temperature | ±0.5°C 
                (up to 60°C), ±1°C (outside);±1.0°F (up to 140°F), ±2°F (outside)
 |   
            | pH Calibration |   | automatic, 
                1 or 2 point with 2 sets of memorized buffer values(pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
 |   
            | Temperature Compensation |   | automatic, 
                -5 to 105°C (23 to 221°F) for pH readings |   
            | Electrode |   | HI 
                1296D amplified pH electrode withinternal temperature sensor, DIN connector and 1 m (3.3') cable 
                (included)
 |  
 HI 991001/2 Meter 
          Specifications
           
            | Battery Type / Life |   | 3 
                x 1.5V AA / approx. 2000 hours of continuous use:auto-off after 8 minutes of non-use
 |   
            | Environment |   | 0 
                to 50°C (32 to 122°F); RH max 100% |   
            | Dimensions |   | 150 
                x 80 x 36 mm (5.9 x 3.1 x 1.4") |   
            | Weight |   | 210 
                g (7.4 oz.) |     |